PLC Specification |
Control System
|
Stored program system
|
Program Language
|
A ladder diagram system
or mnemonic language
|
Number of Sequence Steps
|
5000 steps
|
Number of Command Words
|
27
|
Scan Time
|
10msec
|
Interrupt Mode
|
1msec
|
Memory |
FLASH-ROM
(Sequence program, Metal mold data) |
The Saved Number of Model
Data |
100 metal mold |
Internal Relay |
240 |
Internal Timer |
100 999.9sec or 99.99sec |
External Timer |
100 (Max) 999.9sec or 99.99sec |
Internal Counter |
40 |
External Counter |
40 (Max) |
Input |
Number of Input |
32 |
Input Form |
Sink input |
Rating |
24V |
Output |
Number of Output |
32 |
Output Form |
Sink output Open collector
(1 group as 8 circuits)
|
Rating |
24V 2A |
D/A Output |
Number of Channels |
4 |
Output |
DC 0〜10V 5mA(Variable) |
Output Range |
0.0〜100.0 % |
Resolution |
10000 |
Internal Relay |
80 (Max) |
|
A/D Input |
Number of Channels |
4 (Position)、2 (Analog) |
Input |
DC 0〜5V |
Resolution |
10000 |
Internal Relay |
80 (Max) |
High-Speed
Counter |
Number of channels |
2 + 1(RPM) |
Maximum Input Frequency |
1 KHz |
Number of Maximum Counters |
9999, 999.9(RPM) |
Temperature |
Number of Channels |
7 |
Oil Temperature Display |
1 |
Input Type |
CA(K), (J)TYPE |
Temperature Range |
0〜499℃ |
Control Method |
PID control |
Alarm Judging |
Maximum, Minimum,
Sensor disconnection |
Heater Output |
7 (Open collector 1A) |
Connector |
Input
: Terminal block
Output : Terminal
|
General
Use |
Connector |
Molex/ Terminal (option) |
Temperature of Preservation |
-10℃〜70℃ |
Temperature of Operation |
0℃〜50℃ |
Humidity of Operation |
45%〜85% RH
(Not dew condensation.) |
Power Supply |
DC 24V |
Size |
(W)243mm X (D)192mm X (H)50mm |
|